Pyro chem kitchen knight ii manual pdf

Pyro chem authorized distributors have been extensively trained in system design, installation and maintenance. The pyrochem kitchen knight ii system has available three different size. Have your pyro chem distributor determine the cause of the system actuation. Kitchen knight ii systems archives page 2 of 9 fire. Pyro chem continues to perform extensive research and development on kitchen knight ii. The pyro chem kitchen knight ii system has available three different size. The system is designed to maximize hazard protection, reliability, and installation efficiency. Pyro chem 550185 gv250 gas valve, mechanical, direct cable hookup, 212 in. View and download pyro chem kitchen knight ii technical manual online.

Pyro chem kitchen knight ii fire suppression test performed on a commercial deep fat fryer sound not very good. Kitchen knight ii restaurant fire suppression system pyrochem. View online or download pyro chem kitchen knight ii technical manual. Authorized pyro chem the next revision of the pyrochem technical manuals for kitchen knight il, monarch. The henny penny pressure fryer protection limitations must be followed as outlined in the pyro chem kitchen knight ii restaurant fire suppression technical manual part no. A reset relay is required whenever an electrical gas shutoff valve is used in conjunction with the pyro chem kitchen knight ii restaurant fire suppression system. Therefore, people can be evacuated from the protected area in the presence of fm200 at design concentrations. Pyrochem kitchen knight ii systemthe pyrochem kitchen knight ii pre engineered system utilizes a wet chemical specifically designed to. See fusible link detector installation section of this chapter for fusible link installation guidelines. Pyro chem kitchen knight ii restaurant fire suppression. Refer to pyro chem kitchenknight iirestaurant fire suppression system manual, part no. Deep fat fryers, for instance, heat up quickly, cool slowly and have a high autoignition temperature, meaning if they combust, the fire is extra dangerous. The kitchen knight ii system has been tested and approved in accordance with the ul testing standard for kitchen cooking areas, standard ul300. Immediately after discharge, call your authorized pyro chem distributor to inspect and recharge your fire suppression system.

Pyro chem kitchen knight ii restaurant fire suppression system ul ex 3830 912007 page 4 before resuming business 1. Pyrochem kitchen knight ii presentation uap building. That a pyro chem kitchen knight il restaurant fire suppression system or monarch industrial fire suppression system could fail to activate in a fire. Kitchen knight ii restaurant fire suppression manual ul ex3830 ulc ex3830 2014nov10 rev. The fire extinguishing agent is a potassium carbonatebased water solution that knocks the flame down, cuts off air to the burning grease and cools the hazard area to help ensure the fire stays out. Kitchen knight ii restaurant fire suppression system. Pyro chem continues to perform extensive research and development on kitchen. Pyrochem kitchen knight ii guardian fire protection. The kitchen knight ii system has been tested and approved in accordance with the ul testing standard fostandard ul300. Premium extinguishing agent provides rapid flame knockdown and helps prevent reignition. The kitchen knight ii restaurant kitchen fire suppression system is a preengineered solution to appliance and ventilating hood and duct grease fires. The conduit is connected to the enclosure through a top knockout.

Data kitchen knight ii specification sheet suppression system. Pyrochem kitchen knight ii pipe volumes conversion chart. Pyro chem kitchen knight ii recommends that transition ducts be protected as follows. Pyro chem 551188 rl300 kitchen knight ii wet chemical 3 gal.

Transition ducts larger to smaller in cases where the ductplenum interface opening is larger than the final exhaust duct, measure the perimeterdiameter of the duct halfway between the largest and smallest section or the average perimeterdiameter. Those who install, operate, recharge, or maintain these fire suppression systems should read this entire manual. The kitchen knight ii restaurant fire suppression system is a preengineered solution to appliance, ventilating hood and duct fires. February 11, 2016 authorized pyro chem kitchen knight il and monarch distributors. Pyrochem kitchen knight ii commercial kitchen environments have been changing rapidly over the years, and every new upgrade for cooking efficiency brings a whole new level of fire risk. Pyro chem authorised distributors have been extensively trained in system design, installation and maintenance. Pyro chem kitchen knight ii owners manual 51 kb range guard owners manual 1052 kb paint booth industrial systems. National association of fire equipment distributors. Pc20030361 for more information about fm200 systems or other pyro chem products.

Pyro chem fm200 fire suppression system pyro chem fm200 fire suppression system. Kitchen knight installation manual kitchen knight ii restaurant fire suppression manual ul ex3830 ulc ex3830 2014nov10 rev. Design, installation, recharge, and maintenance manual. It is a preengineered type as defined by nfpa17a standard for wet chemical extinguishing systems and is designed to provide f ire protection for restaurant cooking appliances, hoods, and ducts. Dedicated manual pull station allows immediate actuation at the first sign of fire and provides backup to the automatic detection system. Pyrochem kitchen knight ii presentation uap free download as powerpoint presentation.

Kitchen knight ii fire supression system from pyrochem youtube. The pyro chem kitchen knight ii restaurant fire suppression system is a preengineered system providing flexible, effective fire protection. The model sm24120 can be used as a reset relay when required. This agent is available for cylinder recharging in 3. Plenum type points ft ft manual for more detail single bankv bank 1h 1 4 10 0 6 from. Ventilation systems ductless restaurant ventilation. Pyrochem kitchen knight ii restaurant fire suppression. Kitchen knight ii systems archives fire safety supply. Automatic detection and actuation controls provide 24hour protection. Specifications pyro chem pyrochem design manual, a coursebook, a dictionary, a collection of stories or a monograph on your device. Automatic or manual system activation releases a throttle discharge. The system employs a potassium carbonatebased wet agent that knocks down flames, cuts off air to the burning grease and cools the hazard area to help prevent reflash. Data kitchen knight ii specification sheet suppression.

Scribd is the worlds largest social reading and publishing site. The agent used in pyro chem kitchen knight ii systems is a potassium carbonate based solution that is extremely effective for grease related kitchen fires. Association standards, nfpa 17a standard for wet chemical systems, and nfpa 96 standard for ventilation control and fire protection of commercial cooking operations, and comply with all local andor state codes and standards. Pyro chem fm200 systems are recommended when one or more of the following conditions exist. Pyro chem one stanton street marinette, wi 54143 800 5261079 usa canada 7157323465 international. Pyro chem kitchen knight system components flame tamer. The pyro chem kitchen knight ii system offers breakthrough technology in the industrys most flexible and effective suppression system. Tyco safety products one stanton street marinette, wi54143 28. The pyro chem system plc240300 kitchen knight ii utilizes a wet chemical agent. Protex ii technical manual welcome to heiser protex 2000 system components. Pyro chem kitchen knight ii corner pulleys must be used whenever a change in conduit direction is necessary. Automatic or manual system actuation releases a discharge of agent on the protected area in the form of fine droplets to suppress fire. Pyro chem kitchen knight ii system allstate fire equipment. The operating temperature range of the pyro chem kitchen knight ii system is 32 f to 120 f 0 c to 49 c.

Attendant ii gas station fire protection kitchen knight ii cooking area fire protection monarch industrial fire protection. Fire protection equipment herbert williams fire equipment ltd. Side perimeter diameter length duct type points in in in in rectanglecircular 2d 2 34 100 31 78 unlimited. Expanded capability provides remote manual actuation, gas equipment shutdown, and electrical system shutdown. The kitchen knight ii system provides efficient, reliable protection the moment a fire is detected via a versatile wet chemical distribution network, combined with dual, independent actuation capability.

The insider uses the pyro chem restaurant fire suppression system. National association of fire equipment distributors chicago. The pyro chem kitchen knight ii system employs a potassium carbonatebased wet agent that knocks down flames, cuts off air to the burning grease and cools the hazard area to help prevent reflash. Those who install, operate, recharge, or maintain these fire suppression systems should read this entire. Pyrochem kitchen knight ii fire test demonstration. Automatic or manual system activation releases a throttle discharge of potassium carbonate solution on the protected area in the form of fine droplets to suppress. The automatic pyro chem kitchen knight ii system is incorporated into our odorfree downdraft filtration system and meets the requirements of standard ul300.

Before attaching the stainless steel cable to the fusible link. For msds information, contact pyro chem at 8005261079 or 7157323465 or. The pyrochem kitchen knight ii system can protect all these diverse hazard areas and perform all the necessary auxiliary functions. Badger industry guard owners manual 414 kb important. Dedicated manual actuation system cylinder valve assembly and gas shutoff valve are fully assembled and 100% inspected by pyro chem. Services products resources about us maintenance join our team. View and download pyrochem kitchen knight ii technical manual online. Automatic or manual system activation releases a throttle discharge of potassium carbonate solution on the protected area in the form of fine. The wet chemical discharge pattern is maintained for a duration of time to ensure suppression and inhibit reignition. Kitchen knight ii restaurant fire suppression system kitchen knight ii restaurant fire suppression manual ul ex3830 ulc ex3830 2014nov10 rev. Plenum type points ft ft manual for more detail single bankv bank 1h 1 4 10 0 6 from end of plenum nozzle flow max.

Kitchen knight suppression system installation manual. Refer to pyro chem kitchen knight ii restaurant fire suppression system manual, part no. Automatic or manual system activation releases a throttle. Kitchen and restaurant fire suppression systems pyrotech inc. This manual is intended for use with pyro chem kitchen knight ii restaurant fire suppression systems. Ii ce compliant kitchen knigh t ii systems offer a complete menu of cost effective fire protection components. However the manual does not address page 727 pyro chem installation manual chateiland. A manual pull station is also included for added safety. The operating temperature range of the pyro chem k i t c h e n k n i g h tii system is 32 f to 120 f 0 c to 49 c.

133 1125 79 158 765 847 556 977 980 379 133 1219 1628 343 1712 693 132 1156 1696 80 1549